REQUEST INFORMATION AND CATALOG
REQUEST INFORMATION AND CATALOG

DC Electromagnet – Neodymium Quality (IMAVP/ND)

Degree of protection: IP65 Thermal class: B (130ºC) Rated voltage: 24 VDC Standard duty cycle: see table Other voltages, DI or sizes: Consult us

Description

Electro-permanent direct current:

These electromagnets in their standard models are manufactured at a voltage of 24vdc, but on demand they are manufactured at any voltage, these unlike the IMAVEM models do not require power supply for the generation of the magnetic field, this power supply will only be used to annul the magnetic field and thus be able to release the piece.

In this case, the electrical connection time is very short, as only short pulses are required to release the load. They can also be used with long working coefficients or even continuously if required.

These electromagnets are used for automation, robotics, manipulation, safety, etc.

They are also important where, for safety reasons, safety is required in the maintenance of the field, even if there is a power failure.

Features:

Degree of protection IP65
Thermal Class B (130)
Rated voltage 24V DC

Normalised Duty cycle: see table
For other voltages, ED or sizes, please consult us.

A permanentelectric electromagnet is a device aimed at transforming electrical energy into mechanical energy. Direct current electromagnet are produced in ferric alloys and operate at 24 V. Their functioning is very simple: their magnetic field is concentrated in iron armature, thus permiting any type of pick-up. When it is connectes to the current, this magnetic field is eliminated, allowing the charge to release. When the tension increases, the magnet recovers its initial strenght.

Supply possibilities on request:

Standard terminals included free-of-charge, for all sizes.

IMAVP20/ND,IMAVP30/ND, IMAVP40/ND: 2×0,25mm2
IMAVP50/ND, IMAVP65/ND, IMAVP100/ND: 3×0,5mm2
IMAVP150/ND: 2×0,75mm2

For operating factors and voltages other than standard, deviations from the standard installation or other sizes, please consult us.

The following table gives the holding force values (Fm) according to the air gap (δL) and measured under the following conditions:

  • Dc supply (DC).
  • Flat holding piece (<3μ roughness) in AºSt37, the thickness of which is indicated in the table and dimensions to be greater than the magnetic face of the electromagnet.
  • 20 ° C ambient temperature.
  • Coil stabilized at its working temperature.

Under any other conditions, the magnetic force (Fm) may decrease.

Model Code P (W) ED (%) E (mm) Air gap (mm) δL
0 0.2 0.5

Holding force values Fm (N) 

VP-20 ELEE01030 11.6 20 1 22 7 1.7
3 39 7 1.7
10 39 7 1.7
VP-30 ELEE01016 25 20 1 46 34 22
3 181 74 22
10 181 74 22
VP-40 ELEE01036 42 15 1 51 36 23
3 205 89 38
10 270 89 38
VP-50 ELEE01018 48 15 1 60 41 34
3 304 200 95
10 607 225 110
VP-65 ELEE01074 80 15 1 70 50 40
3 374 340 260
10 1220 750 400
VP-100 ELEE01053 75 25 1 83 61 49
3 421 365 338
10 2254 1254 686
VP-150 ELEE01108 77 40 1 78 46 32
3 615 475 401
10 2205 1490 1100

 

e (mm): thickness of the piece to hold

Standard sizes:

  • Free terminals: Ref: IMAVEM (type) -V-ED%

Model Code ØA (-0.3) (mm) M C (±0.1) (mm) D (mm) E (mm) Weight (kg)
VP-20 ELEE01030 20 M-3 25 5 26 0.04
VP-30 ELEE01016 30 M-4 28 6 35.2 0.13
VP-40 ELEE01036 40 M-5 41.7 6 42.7 0.28
VP-50 ELEE01018 50 M-5 42.8 6 52.5 0.45
VP-65 ELEE01074 65 M-8 45.5 8 67 0.74
VP-100 ELEE01053 100 M-8 67 10 102 3.00
VP-150 ELEE01108 150 M-16 65 15 152 7.10

Important: the clamp screw must not exceed the dimension D.

* On request, can be manufactured with internal protection to prevent overheating in the coil due to non-compliance with operating times determined by the driving factors, this overheating can demagnetize the internal magnets or destroy the coil altering the correct operation of the electromagnet.

Remarks:

Power mode to nullify the magnetic field:
Voltage: 24Vdc
Polarization: Red wire + VDC / black Cable -VDC
Order code: IMAVP–/ND –V ED–%

Rated voltage: 24V dc; Load factor

  • Example1: IMAVP50/ND ; Rated voltage: 24 Vdc; Load factor: ED15%; Ref: IMAVP50/ND 24Vdc ED15%
  • Ejxample2: IMAVP50/ND with protection; Rated voltage: 24 Vdc; Load factor: ED15%; Ref: IMAVP50/ND_WP 24Vdc ED15%

Grounding is recommended if the metallic parts are accessible.

When used for lifting and handling of loads a minimum safety factor of 3 should be used, the weight of the load must be at least one third of the holding force.

View 360º

Click on the image, hold down and turn

Web desarrollada por 
Volcanic Internet
info