Electromagnet ER60-10/C

Protection rate: IP00 Insulation class: B (130ºC) Cycle duration: 5 minutes Standard stroke "s": 10mm Temperature rise "DV31": 70ºC Work: pull/push Incorporated return spring: YES
Description

Features:

Electromagnet protection rate: IP00
Insulation class: B (130ºC)
Cycle duration: 5 minutes
Standard stroke "s": 10mm
Temperature rise "DV31": 70ºC
Work: pull/push
Return spring incorporated: YES

Duty-cycle ED(%)) 100 40 25 15 5
Abs. Power at 20ºC (W) 18 45 70 110 280
Minimum force (N) 12 24 32 44 80
Max time under voltage(s) 120 75 45 15
Plunger weight (g)   117
Solenoid weight (g)   650
Duty-cycle ED(%) Standard voltages Under demand voltages
VDC VAC VDC VAC
6 12 24 48 100 125 205 110 230 Min Max Min Max
100% X O O O O O O O O 7 230 48 230
40% X O O O O O O X O 11 230 125 230
25% X X O O O O O X O 13 230 200 230
15% X X O O O O O X X 16 230 X X
5% X X O O O O O X X 24 230 X X

Layout::    O= Available;     X= Unavailable

Force stroke curve and Solenoid under voltage:* Under request, it can be supplied in any other dimension..

 

Remarks:

  1. Voltage under demand: They can be manufactured at any voltage between the maximum and minimum voltage values shown in the chart.
  2. To feed in alterning current the solenoid will have a rectifier incorporated in the coil.
  3. The duty cycles described in the chart are standard, they can be manufactured in any intermediate cycle.
  4. If any variation from the original is needed, please ask us.
  5. The terminals can be changed by leads.
  6. Earthing is recommended if the metallic parts are accessible.

Ordering code: ER60-10/C --V ED---% - Mounting position - Spring

Example:

  • Standard voltage:24Vdc Duty cycle: ED100%: Mounting position A: With spring : ER60-10/C 24Vdc ED100% A RS
  • Standard voltage:48Vdc Duty cycle: ED15%: Mounting position C: Without spring : ER60-10/C 48Vdc ED15% C RN

 