REQUEST INFORMATION
REQUEST INFORMATION

Electromagnet ER35/C

Protection rate: IP00 Insulation class: B (130ºC) Cycle duration: 2 minutes Standard stroke "s": 12 mm Temperature rise "DV31": 70ºC Work: pull/push Incorporated return spring: YES
Description

Features:

Electromagnet protection rate: IP00
Insulation class: B (130ºC)
Cycle duration: 2 minutes
Standard stroke "s": 12 mm
Temperature rise "DV31": 70ºC
Work: pull/push
Return spring incoporated: YES

Duty-cycle ED(%) 100 40 25 15 5
Abs. Power at 20ºC (W) 9 20 35 60 150
Minimum force (N) 1.5 4.3 7.5 10.6 17.3
Max time under voltage(s) 48 30 18 6
Plunger weight (g)    34
Solenoid weight (g)   170
Duty-cycle ED(%)) Standard voltages Under demand voltages
VDC VAC VDC VAC
6 12 24 48 100 125 205 110 230 Min Max Min Max
100% O O O O O O O O O 4 230 36 230
40% O O O O O O O O O 5 230 75 230
25% O O O O O O O O O 6 230 105 230
15% X O O O O O O X O 8 230 180 230
5% X O O O O O O X X 12 230 X X

Layout::     O= Available;      X= Unavailablee

Force stroke curve and Solenoid under voltage:

* On request, it can be supplied in any other dimension.

Remarks:

  1. Voltage under demand: They can be manufactured at any voltage between the maximum and minimum voltage values shown in the chart.
  2. To feed in alterning current the solenoid will have a rectifier incorporated in the coil.
  3. The duty cycles described in the chart are standard, they can be manufactured in any intermediate cycle.
  4. If any variation from the original is needed, please ask us.
  5. The terminals can be changed by leads.
  6. Earthing is recommended if the metallic parts are accessible.

Ordering code: ER35/C --V ED---% - Mounting position - Spring

Example:

Standard voltage:24Vdc Duty cycle: ED100%: Mounting position A: With spring : ER35/C 24Vdc ED100% A RS
Standard voltage:12Vdc Duty cycle: ED15%: Mounting position C: Without spring : ER35/C 12Vdc ED15% C RN

 