The three-phase IP-00 transformers are used to change the voltage value and adapt it to the need, they are also very useful for installations where there are small voltage peaks or electrical noises, improving quality. The three-phase transformers are dry type and tropicalized, this provides great protection against corrosion, high electrical insulation and this increases the quality and durability of the product.
There is the possibility of manufacturing custom products if the standard specifications are not those required by the customer.
Technical characteristics:
Concept |
Values |
Isolation |
Class F |
Frequency |
50-60Hz |
Type of protection |
IP-00 |
Maximum ambient temperature |
45ºC |
Copper type |
HC-210º |
Dielectric strength |
>4000v |
Primary voltage |
100 - 500 + N |
Secundary voltage |
100 - 500 + N |
REFERENCES:
You can consult the different models of the TTR series of three-phase transformers in the following reference table.
MODEL |
POWER |
LOSSES |
Vcc % |
WIDTH |
BACKGROUND |
TALL |
FIXATION |
FIXATION |
FIXATION |
WEIGHT |
Ref. |
VA |
W |
UL |
A m/m |
B m/m |
C m/m |
D m/m |
E m/m |
Ø m/m |
KG |
TTR-01 |
100 |
19 |
10 |
120 |
80 |
110 |
90 |
60 |
6,5 |
2,7 |
TTR-03 |
300 |
32 |
10 |
150 |
90 |
135 |
110 |
60 |
6,5 |
5,8 |
TTR-05 |
500 |
77 |
9 |
180 |
120 |
165 |
140 |
90 |
6,5 |
8,8 |
TTR-1 |
1.000 |
98 |
6,5 |
180 |
130 |
165 |
140 |
100 |
6,5 |
13 |
TTR-2 |
2.000 |
122 |
5 |
240 |
140 |
220 |
200 |
110 |
8 |
21 |
TTR-3 |
3.000 |
176 |
5 |
240 |
140 |
220 |
200 |
110 |
8 |
24 |
TTR-5 |
5.000 |
230 |
4,6 |
300 |
165 |
270 |
200 |
135 |
8 |
32 |
TTR-7 |
7.000 |
330 |
4,5 |
360 |
200 |
380 |
320 |
160 |
8 |
56 |
TTR-10 |
10.000 |
431 |
4,5 |
360 |
220 |
380 |
320 |
180 |
8 |
68 |
TTR-12 |
12.000 |
510 |
4,4 |
420 |
230 |
460 |
350 |
190 |
10 |
89 |
TTR-15 |
15.000 |
725 |
4,4 |
420 |
240 |
460 |
350 |
200 |
10 |
101 |
TTR-20 |
20.000 |
815 |
4,3 |
420 |
250 |
460 |
350 |
210 |
10 |
122 |
TTR-25 |
25.000 |
1.040 |
4,1 |
480 |
290 |
530 |
400 |
240 |
12 |
163 |
TTR-30 |
30.000 |
1.080 |
4,1 |
480 |
330 |
530 |
400 |
280 |
12 |
180 |
TTR-40 |
40.000 |
1.235 |
4,1 |
640 |
340 |
640 |
500 |
290 |
14 |
252 |
TTR-50 |
50.000 |
1.680 |
4,1 |
640 |
350 |
640 |
500 |
300 |
14 |
288 |
TTR-75 |
75.000 |
2.010 |
4 |
640 |
360 |
640 |
500 |
310 |
14 |
375 |
TTR-100 |
100.000 |
2.450 |
4 |
720 |
430 |
730 |
600 |
380 |
15 |
465 |
TTR-125 |
125.000 |
2.700 |
4 |
720 |
450 |
730 |
600 |
410 |
15 |
490 |
TTR-150 |
150.000 |
3.010 |
3,9 |
720 |
480 |
730 |
700 |
400 |
15 |
700 |
TTR-200 |
200.000 |
3.560 |
3,9 |
720 |
540 |
730 |
700 |
430 |
15 |
760 |
Applications:
The three-phase IP-00 transformers are used for:
- Galvanic isolation of three-phase installations to improve safety.
- Generate Neutral in facilities that do not have it.
- Installations where there are small voltage peaks or electrical noises, improving the quality of the signal that will feed the loads.
- Installations that leak to the ground, and require galvanic isolation to ensure the supply avoiding the trip of the general differential switch.
Observations:
The three-phase IP-00 transformers are manufactured according to IEC 96-2, IEC-742, EN-60742 and the indicated data can be modified as needed, without prior notice.