IMA 100 / C Features:
Protection degree: IP00 Thermal class: B (130ºC) Reference cycle time: 60 minutes These power supplies are especially suitable for supplying the DC electromagnets of the IMAVEM and IMAREC models, providing a high degree of safety since they admit voltages of input between 85v to 264v, the DC voltage can be adjusted ± 10%.
MODEL |
RS-100-3.3 |
RS-100-5 |
RS-100-12 |
RS-100-15 |
RS-100-24 |
RS-100-48 |
OUTPUT |
DC VOLTAGE |
3.3V |
5V |
12V |
15V |
24V |
48V |
VOLTAGE RANGE |
20A |
16A |
8,5A |
7A |
4,5A |
2,3A |
NOMINAL CURRENT |
0≈20A |
0≈16A |
0≈8,5A |
0≈7A |
0≈4,5A |
0≈2,3A |
NOMINAL POWER |
66W |
80W |
102W |
105W |
108W |
110,4W |
RIPPLE AND NOISE |
80mVp-p |
80mVp-p |
120mVp-p |
120mVp-p |
120mVp-p |
200mVp-p |
RANGE VOLTAGE |
3,2V≈3,5V |
4,75V≈5,5V |
11,4V≈13,2V |
14,25V≈16,5V |
22,8V≈26,4V |
45,6V≈52,8V |
VOLTAGE TOLERANCE |
±3,0% |
±2,0% |
±1,0% |
±1,0% |
±1,0% |
±1,0% |
LINE REGULATION |
±0,5% |
±0,5% |
±0,5% |
±0,5% |
±0,5% |
±0,5% |
LOAD REGULATION |
±2,0% |
±1,0% |
±0,5% |
±0,5% |
±0,5% |
±0,5% |
SETTING |
500ms, 20ms/230VAC / 1200ms, 30ms/115VAC full loaded |
WAIT TIME |
100ms/230VAC / 18ms/115VAC full loaded |
INPUT |
VOLTAGE RANGE |
88≈264VAC / 125≈373VDC (Resistencia 300VAC, 5 second waves. without damage) |
FREQUENCY RANGE |
47≈63Hz |
EFFICIENCY (Type) |
74% |
77% |
81% |
82% |
84% |
84% |
AC CURRENT (Type) |
2,5A/115VAC / 1,5A/230VAC |
CURRENT "INRUSH" (Type) |
Cold start 40A/230VAC |
LEAKAGE CURRENT |
<2mA / 240VAC |
PROTECTION |
OVERLOAD |
110≈150% rated output power |
Protection type: Hipo mode, recovers automatically after clearing the fault. |
OVERVOLTAGE |
3,8V≈4,45V |
5,75V≈6,75V |
13,8V≈16,2V |
17,25V≈20,25V |
27,6V≈32,4V |
55,2V≈64,8V |
Protection type: Hipo mode, recovers automatically after clearing the fault. |
ENVIRONMENT |
WORK TEMPERATURE |
-25≈+70ºC (See the output load reduction curve) |
WORKING HUMIDITY |
20≈90% RH (no condensation) |
STORAGE |
-40≈+85,10≈95% RH |
COEFFICIENT TEMPERATURE |
±0,03%/ºC (0≈50ºC) |
VIBRATION |
10≈500Hz, 5G 10 min. / 1 cycle, 60 min period. each along the X, Y, Z axes. |
SECURITY |
SAFETY STANDARDS |
UL60950-1, TUV EN60950-1 approved |
SUPPORTED VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
INSULATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
EMI DRIVING AND RADIATION |
Compliance with EN55022 (CISPR22) Class B |
HARMONIC CURRENT |
Compliance with EN61000-3-2, -3 |
EMS IMMUNITY |
Compliance with EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criterion A |
Mechanical Specifications:
* Upon request, they can be supplied in any other dimension.