REQUEST INFORMATION AND CATALOG
REQUEST INFORMATION AND CATALOG

IMA-100 / ELEF01633

IMA 100 / C Features: Protection degree: IP00 Thermal class: B (130ºC) Reference cycle time: 60 minutes These power supplies are especially suitable for supplying the […]
Description

IMA 100 / C Features:

Protection degree: IP00 Thermal class: B (130ºC) Reference cycle time: 60 minutes These power supplies are especially suitable for supplying the DC electromagnets of the IMAVEM and IMAREC models, providing a high degree of safety since they admit voltages of input between 85v to 264v, the DC voltage can be adjusted ± 10%.

MODEL RS-100-3.3 RS-100-5 RS-100-12 RS-100-15 RS-100-24 RS-100-48
OUTPUT DC VOLTAGE 3.3V 5V 12V 15V 24V 48V
VOLTAGE RANGE 20A 16A 8,5A 7A 4,5A 2,3A
NOMINAL CURRENT 0≈20A 0≈16A 0≈8,5A 0≈7A 0≈4,5A 0≈2,3A
NOMINAL POWER 66W 80W 102W 105W 108W 110,4W
RIPPLE AND NOISE 80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p
RANGE VOLTAGE 3,2V≈3,5V 4,75V≈5,5V 11,4V≈13,2V 14,25V≈16,5V 22,8V≈26,4V 45,6V≈52,8V
VOLTAGE TOLERANCE ±3,0% ±2,0% ±1,0% ±1,0% ±1,0% ±1,0%
LINE REGULATION ±0,5% ±0,5% ±0,5% ±0,5% ±0,5% ±0,5%
LOAD REGULATION ±2,0% ±1,0% ±0,5% ±0,5% ±0,5% ±0,5%
SETTING 500ms, 20ms/230VAC          /          1200ms, 30ms/115VAC full loaded
WAIT TIME 100ms/230VAC          /          18ms/115VAC full loaded
INPUT VOLTAGE RANGE 88≈264VAC / 125≈373VDC (Resistencia 300VAC, 5 second waves. without damage)
FREQUENCY RANGE 47≈63Hz
EFFICIENCY (Type) 74% 77% 81% 82% 84% 84%
AC CURRENT (Type) 2,5A/115VAC          /          1,5A/230VAC
CURRENT "INRUSH" (Type) Cold start 40A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
PROTECTION OVERLOAD 110≈150% rated output power
Protection type: Hipo mode, recovers automatically after clearing the fault.
OVERVOLTAGE 3,8V≈4,45V 5,75V≈6,75V 13,8V≈16,2V 17,25V≈20,25V 27,6V≈32,4V 55,2V≈64,8V
Protection type: Hipo mode, recovers automatically after clearing the fault.
ENVIRONMENT WORK TEMPERATURE -25≈+70ºC (See the output load reduction curve)
WORKING HUMIDITY 20≈90% RH (no condensation)
STORAGE -40≈+85,10≈95% RH
COEFFICIENT TEMPERATURE ±0,03%/ºC (0≈50ºC)
VIBRATION 10≈500Hz, 5G 10 min. / 1 cycle, 60 min period. each along the X, Y, Z axes.
SECURITY SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved
SUPPORTED VOLTAGE I/P-O/P:3KVAC     I/P-FG:1.5KVAC     O/P-FG:0.5KVAC
INSULATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI DRIVING AND RADIATION Compliance with EN55022 (CISPR22) Class B
HARMONIC CURRENT Compliance with EN61000-3-2, -3
EMS IMMUNITY Compliance with EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criterion A

Mechanical Specifications: 

* Upon request, they can be supplied in any other dimension.