Description
Features:
Electromagnet protection rate: IP00
Insulation class: B (130ºC)
Cycle duration: 3 minutes
Standard stroke “s”: 5mm
Temperature rise “DV31”: 70ºC
Work: pull/push
Return spring incorporated: YES
| Duty-cycle ED(%) | 100 | 40 | 25 | 15 | 5 |
| Abs. Power at 20ºC (W) | 12 | 30 | 48 | 80 | 240 |
| Minimum force (N) | 0.1 | 6.3 | 10.6 | 14.4 | 35 |
| Max time under voltage(s) | ∞ | 60 | 38 | 23 | 8 |
| Plunger weight (g) | 59 | ||||
| Solenoid weight (g) | 285 | ||||
| Duty-cycle ED(%) | Standard voltages | Under demand voltages | |||||||||||
| VDC | VAC | VDC | VAC | ||||||||||
| 6 | 12 | 24 | 48 | 100 | 125 | 205 | 110 | 230 | Min | Max | Min | Max | |
| 100% | O | O | O | O | O | O | O | O | O | 5 | 230 | 34 | 230 |
| 40% | X | O | O | O | O | O | O | O | O | 7 | 230 | 86 | 230 |
| 25% | X | O | O | O | O | O | O | X | O | 9 | 230 | 136 | 230 |
| 15% | X | O | O | O | O | O | O | X | O | 11 | 230 | 230 | 230 |
| 5% | X | X | O | O | O | O | O | X | X | 16 | 230 | X | X |
Layout: O= Available; X= Unavailable
Force stroke curve and Solenoid under voltage:

* Under request, it can be supplied in any other dimension.
Remarks:
- Voltage under demand: They can be manufactured at any voltage between the maximum and minimum voltage values shown in the chart.
- To feed in alterning current the solenoid will have a rectifier incorporated in the coil.
- The duty cycles described in the chart are standard, they can be manufactured in any intermediate cycle.
- If any variation from the original is needed, please ask us.
- The terminals can be changed by leads.
- Earthing is recommended if the metallic parts are accessible.
Ordering code: ER45-05/C –V ED—% – Mounting position – Spring
Example:
- Standard voltage:24Vdc Duty cycle: ED100%: Mounting position A: With spring : ER45-05/C 24Vdc ED100% A RS
- Standard voltage:12Vdc Duty cycle: ED15%: Mounting position C: Without spring : ER45-05/C 12Vdc ED15% C RN