DRT 960W Three Phase

  • Three Phase AC 340 ~ 550V wide range input
  • High efficiency 91% and low dissipation
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Optional parallel function (1+1)
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 o 15
  • UL 508 (Industrial control equipment) approved
  • EN61000-6-2 (EN50082-2) industrial immunity level
  • 100% full load burn-in test
  • 3 years warranty

Out of stock

SKU: aaaa776-1-1 Categories: , , , ,

Description

960W Three Phase Industrial DIN RAIL Power Supply

MODELDRT-960-24DRT-960-48
OUTPUTDC VOLTAGE24V48V
RATED CURRENT40A20A
CURRENT RANGE0~40A0~20A
RATED POWER960W960W
RIPPLE & NOISE (max) *280mVp-p80mVp-p
VOLTAGE ADJ. RANGE24~28V48~55V
VOLTAGE TOLERANCE *3±1.0%±1.0%
LINE REGULATION±0.5%±0.5%
LOAD REGULATION±0.5%±0.5%
SETUP, RISE TIME200ms, 60ms/400VAC – 200ms, 60ms/VAC at full load
HOLD UP TIME14ms/400VAC – 30ms/500VAC at full loaded
INPUTVOLTAGE RANGEThree-Phase 340 – 550 VAC (Dual phase operation possible in connecting L1, L3, FG)*5
FREQUENCY RANGE47~63Hz
EFFICIENCY (Typ.)91%92%
AC CURRENT (Typ.)2A/400VAC – 1.6A/500VAC
INRUSH CURRENT (max)COLD START 50A
LEAKAGE CURRENT<3.5Ma/530VAC
PROTECTIONOVERLOAD105~125% rated output power
Protection type: Constant current limiting, unit will shut down o/p voltage after 3 sec. Re-power on to recover
OVER VOLTAGE30~36V59~66V
Protection type: Shut down o/p voltage. Re-power on to recover
OVER TEMPERATUREShut down o/p voltage, recovers automatically after temperature goes down
ENVIRONNEMENTWORKING TEMP.-20~+60ºC (Refer to “Derating Curve”)
WORKING HUMIDITY20~90% RH non-condensing
STORAGE TEMP., HUMIDITY-40~+85ºC, 10~95 RH non-condensing
TEMP. COEFFICIENT±0.03%/ºC (0~50ºC)
VIBRATIONComponent:10~500Hz, 2G 10min/1cycle, 60min each along X, Y, Z axes; Mounting: Compilance to IEC 60068-2-6
SAFETY & EMCSAFETY STANDARDSUL508, UL60950-1, TUV EN60950-1, EAC TP TC 004 approved
WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500 VDC / 25ªC / 70% RH
EMC EMISSIONCompilance to EN55011 (CISPR11), EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITYCompilance to EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 (EN50082-2), heavy indutry level, criteria A, EAC TP TC 020
OTHERSMTBF122.5K hrs min. MIL-HDBK-217F (25ªC)
DIMENSION276*125,2*100mm (W*H*D)
PACKING3.3Kg; 4pcs/14,2Kg/1.14CUFT
NOTE*1 All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25ºC of ambient temperature
*2 Ripple & Noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
*3 Tolerance: includes set up tolerance, line regulation and load regulation.
*4 The power supply is considered a component which will be installed into a final equipment. It must be re-confirmed that it still mets EMC directives
*5 Dual phase operation (connecting L1, L3, FG) is allowed under certan derating to output load. Please refer to the derating curves for details
*6 The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altidude higher than 2000m(6500ft)