Features:
Electromagnet protection rate: IP00
Insulation class: B (130ºC)
Cycle duration: 5 minutes
Standard stroke "s": 10mm
Temperature rise "DV31": 70ºC
Work: pull/push
Return spring incorporated: YES
Duty-cycle ED(%)) | 100 | 40 | 25 | 15 | 5 |
Abs. Power at 20ºC (W) | 18 | 45 | 70 | 110 | 280 |
Minimum force (N) | 12 | 24 | 32 | 44 | 80 |
Max time under voltage(s) | ∞ | 120 | 75 | 45 | 15 |
Plunger weight (g) | 117 | ||||
Solenoid weight (g) | 650 |
Duty-cycle ED(%) | Standard voltages | Under demand voltages | |||||||||||
VDC | VAC | VDC | VAC | ||||||||||
6 | 12 | 24 | 48 | 100 | 125 | 205 | 110 | 230 | Min | Max | Min | Max | |
100% | X | O | O | O | O | O | O | O | O | 7 | 230 | 48 | 230 |
40% | X | O | O | O | O | O | O | X | O | 11 | 230 | 125 | 230 |
25% | X | X | O | O | O | O | O | X | O | 13 | 230 | 200 | 230 |
15% | X | X | O | O | O | O | O | X | X | 16 | 230 | X | X |
5% | X | X | O | O | O | O | O | X | X | 24 | 230 | X | X |
Layout:: O= Available; X= Unavailable
Force stroke curve and Solenoid under voltage:* Under request, it can be supplied in any other dimension..
Remarks:
Ordering code: ER60-10/C --V ED---% - Mounting position - Spring
Example: