Features:
Electromagnet protection rate: IP00
Insulation class: B (130ºC)
Cycle duration: 2 minutes
Standard stroke "s": 12 mm
Temperature rise "DV31": 70ºC
Work: pull/push
Return spring incoporated: YES
Duty-cycle ED(%) | 100 | 40 | 25 | 15 | 5 |
Abs. Power at 20ºC (W) | 9 | 20 | 35 | 60 | 150 |
Minimum force (N) | 1.5 | 4.3 | 7.5 | 10.6 | 17.3 |
Max time under voltage(s) | ∞ | 48 | 30 | 18 | 6 |
Plunger weight (g) | 34 | ||||
Solenoid weight (g) | 170 |
Duty-cycle ED(%)) | Standard voltages | Under demand voltages | |||||||||||
VDC | VAC | VDC | VAC | ||||||||||
6 | 12 | 24 | 48 | 100 | 125 | 205 | 110 | 230 | Min | Max | Min | Max | |
100% | O | O | O | O | O | O | O | O | O | 4 | 230 | 36 | 230 |
40% | O | O | O | O | O | O | O | O | O | 5 | 230 | 75 | 230 |
25% | O | O | O | O | O | O | O | O | O | 6 | 230 | 105 | 230 |
15% | X | O | O | O | O | O | O | X | O | 8 | 230 | 180 | 230 |
5% | X | O | O | O | O | O | O | X | X | 12 | 230 | X | X |
Layout:: O= Available; X= Unavailablee
Force stroke curve and Solenoid under voltage:
* On request, it can be supplied in any other dimension.
Remarks:
Ordering code: ER35/C --V ED---% - Mounting position - Spring
Example:
Standard voltage:24Vdc Duty cycle: ED100%: Mounting position A: With spring : ER35/C 24Vdc ED100% A RS
Standard voltage:12Vdc Duty cycle: ED15%: Mounting position C: Without spring : ER35/C 12Vdc ED15% C RN
Recent Comments