Features:
Electromagnets protection rate: IP00
Insulation class: B (130ºC)
Cycle duration: 2minutes
Standard stroke “s”: 5mm
Temperature rise “DV31″: 70ºC
Work: pull/push
Return spring incorporated: YES
Duty-cycle ED(%) | 100 | 40 | 25 | 15 | 5 |
Abs. Power at 20ºC (W) | 7.5 | 17 | 25 | 38 | 95 |
Minimum force (N) | 2.5 | 5.4 | 7.5 | 10 | 17 |
Max time under voltage (s) | ∞ | 48 | 30 | 18 | 6 |
Plunger weight (g) | 15 | ||||
Solenoid weight (g) | 85 |
Duty-cycle ED(%) | Standard voltages | Under demand voltages | |||||||||||
VDC | VAC | VDC | VAC | ||||||||||
6 | 12 | 24 | 48 | 100 | 125 | 205 | 110 | 230 | Min | Max | Min | Max | |
100% | O | O | O | O | O | O | X | X | X | 3 | 140 | X | X |
40% | O | O | O | O | O | O | O | X | X | 5 | 220 | X | X |
25% | O | O | O | O | O | O | O | X | X | 5 | 230 | X | X |
15% | O | O | O | O | O | O | O | X | X | 6 | 230 | X | X |
5% | X | O | O | O | O | O | O | X | X | 9 | 230 | X | X |
Layout: O= Available; X= Unavailable
Force stroke curve and Solenoid under voltage:
Electromagnet under tension.
* On request, it can be supplied in any other dimension.
Remarks:
Ordering code: ER30/C --V ED---% - Mounting position - Spring
Example:
ATTENTION: When using for lifting and handling loads must choose a minimum safety factor of 3, the weight of the load must be at least one third of the holding force.